11
Technical data
11.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
11.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB178T2 - 11081759
9...26 VDC (HTL - version C, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...2048 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE
UL approval / E256710
ø287 mm
ø120...150 mm (through hollow shaft)
≤550 N axial
≤800 N radial
IP54
≤3600 rpm (mechanical)
50 Ncm
240 kgcm
Housing: aluminium alloy
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Flange connector M23, 12-pin (option M: 2x)
20 kg (ø150)
Baumer_HOG28-T2_II_DE-EN (19A1)
(ø150)
2
11
Technical data
32