10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Connection:
• Weight approx.:
MB098T1 - 11055709
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
250...2500 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø158 mm
ø20...38 mm (through hollow shaft)
≤450 N axial
≤600 N radial
IP66
≤6000 rpm (mechanical)
15 Ncm
4.9 kgcm
Housing: aluminium alloy
Shaft: stainless steel
-40...+100 °C
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
Terminal box
2x terminal box (option M)
4.9 kg
5.1 kg (option M)
Baumer_HOG16-HOG16M-T1_II_DE-EN (20A2)