Baumer HOGS 75 KC Mounting And Operating Instructions - Page 27

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HOGS 75 KC. Baumer HOGS 75 KC 32 pages. Sine encoder
Also for Baumer HOGS 75 KC: Installation And Operating Manual (32 pages), Mounting And Operating Instructions (32 pages)

Baumer HOGS 75 KC Mounting And Operating Instructions
9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
MB175aT1 - 11173568
5 VDC ±10 % (version DN ...)
9...26 VDC (version DN ... R)
≤90 mA
1024...2048 (as ordered)
90°
Zero pulse, width 90°
Optical
K1, K2, K0 + inverted
SinCos 1 Vpp
-50 dB
≤20 mV
200 kHz (-3 dB)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø75 mm
ø17 mm (cone shaft 1:10)
≤170 N axial
≤250 N radial
IP56
≤10000 rpm (mechanical)
≤4 Ncm
180 gcm²
Housing: aluminium die-cast
Shaft: stainless steel
-20...+70 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Connecting cable
860 g
Baumer_HOGS75K-A-T1_II_DE-EN (19A1)
9
Technical data
24