Baumer HS35 Series Installation And Operating Instruction - Page 41

Browse online or download pdf Installation And Operating Instruction for Media Converter Baumer HS35 Series. Baumer HS35 Series 44 pages.

Baumer HS35 Series Installation And Operating Instruction
13.2

Electrical data

HS35 - general parameters
Voltage supply
Reverse polarity protection Yes
Sensing method
Interference immunity
Emitted interference
Approvals
HS35F
Consumption w/o load ≤40 mA (24 VDC)
Resolution (steps/turn) 1024...80000
Output frequency
Output signals
Output circuit
HS35P
Consumption w/o load ≤50 mA (24 VDC)
Resolution (steps/turn) 1...8192
Output frequency
Output signals
Output circuit
Programmable
parameters
Baumer_HS35_II_DE-EN_1706.indd
4.75...30 VDC
Optical
DIN EN 61000-6-2
DIN EN 61000-6-4
UL approval / file no. E240061, ROHS compliant EU
guideline 2011/65/EG, CE conform
≤130 mA (4.75 VDC) + output load, max. 250 mA
≤300 kHz (TTL), ≤160 kHz (HTL), ≤160 kHz (OC)
A, B, Z
A, B, Z + complement,
½ cycle index gated with negative B channel
Linedriver (TTL, 7272), Vout = 5 V, short-circuit proof
Push-pull (HTL, 7272), Vout = Vin, short-circuit proof
Open Collector (OC, 7273), Vout = Vin, short-circuit proof
≤180 mA (5 VDC) + output load, max. 250 mA
≤300 kHz (TTL), ≤160 kHz (HTL), ≤160 kHz (OC)
A, B, Z
A, B, Z + complement,
½ cycle index gated with negative B channel
Linedriver (TTL, 7272), Vout = 5 V, short-circuit proof
Push-pull (HTL, 7272), Vout = Vin, short-circuit proof
Open Collector (OC, 7273), Vout = Vin, short-circuit proof
Output resolution in increments of one (can be different
for A and B)
Output signal level (TTL or HTL)
Zero pulse width and position
Rotational direction CW/CCW
Technical data
 41