Technical data
8
Technical data
8.1
Technical data - electrical ratings
• Interference immunity:
• Emitted interference:
• Approvals:
8.2
Technical data - electrical ratings (SSI)
• Voltage supply:
• Interface:
• Function:
• Steps per turn:
• Sensing method:
• Code:
• Code sequence:
• Additional output signals:
8.3
Technical data - electrical ratings (square-wave)
• Voltage supply (Signals):
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
At UB = 5 VDC: TTL/RS422; At UB = 10...30 VDC: HTL
5)
23
EN 61000-6-2
EN 61000-6-3
CE
UL
4.5...30 VDC
SSI
Singleturn
≤131072 / 17 bit
Magnetic
Gray or binary
CW default
Square-wave TTL (RS422)
Square-wave universal HTL/TTL
SinCos 1 Vpp
(as ordered)
R...D:
4.5...30 VDC
U...D:
5...30 VDC
≤300 mA
1...262144 (as ordered)
90° ±10°
40...60 %
Magnetic
≤2 MHz
A+, A−, B+, B−
HTL
TTL/RS422
(as ordered)
Baumer_MHAP200-T1_DE-EN_202210_MI_11105054 (22A1)
(TTL/RS422)
(TTL/HTL)
5)
MB221T1 - 11105054