5.

ELECTRICAL CONNECTION

5.1

Terminal significance

Ub
0V
A+
3)
A−
3)
B+
3)
B−
3)
R+
3)
R−
3)
nE+
nE−
PRE
DIR
SP+
4)
SP−
4)
SA
5)
SB
5)
D+
D−
C+
C−
dnu
* Depending on version
Additional output incremental (option)
3)
Speed switch (option)
4)
Programming interface (only HMG10P)
5)
MB244EN - 11171691, 19A2, Baumer_HMG10-SSI_II_EN
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK− / error output inverted
RESET (see also
section
Rotating direction (see also
DSL_OUT1 / speed switch (open collector* or solid state relay*)
DSL_OUT2 / speed switch (0V* or solid state relay*)
RS485+ / programming interface
RS485− / programming interface
SSI data+
SSI data−
SSI clock+
SSI clock−
Do not use
ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
5.2.2)
section
5.2.3)
13/35