Baumer Hubner Berlin HMG 11 Mounting And Operating Instructions - Page 25

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer Hubner Berlin HMG 11. Baumer Hubner Berlin HMG 11 40 pages. Absolute encoder ethercat
Also for Baumer Hubner Berlin HMG 11: Installation And Operating Instructions Manual (48 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (36 pages)

Baumer Hubner Berlin HMG 11 Mounting And Operating Instructions
ELECTRICAL CONNECTION / ELECTRICAL CONNECTION WITH RADIAL FLANGE CONNECTORS
5.8.2

Assignment flange connectors

)
Do not connect voltage supply to outputs! Danger of damage!
Please, beware of possible voltage drop in long cable leads (inputs and out-
puts)!
5.8.2.1
First flange connector [C]
SSI
Programming interface (only HMG10P)
Additional output incremental 1 (option)
Flange connector M23 (male, 17-pin, clockwise)
5.8.2.2
Second flange connector [D]
Additional output incremental 2 (option)
Speed switch (option)
)
Flange connector M23 (male, 12-pin, clockwise)
Additional output incremental (option)
3)
Speed switch (option)
4)
Programming interface (only HMG10P)
5)
MB244EN - 11171691, 19A2, Baumer_HMG10-SSI_II_EN
1
11
2
12
10
13
16
3
9
15
14
4
17
8
5
6
7
The TTL/HTL output at the additional output incremental 2 is electrically
isolated and requires a separate power supply�
8
9
1
12
10
2
7
3
6
11
4
5
PIN
ASSIGNMENT
1
nE−
2
DIR
3
dnu / SB
5)
4
nE+
5
PRE
6
dnu / SA
5)
7
Ub
8
C+
9
C−
PIN
ASSIGNMENT
1
dnu / B−
3)
2
nE−
3
dnu / R+
3)
4
dnu / R−
3)
5
dnu / A+
3)
6
dnu / A−
3)
PIN
ASSIGNMENT
10
0V
11
Internal shield
12
dnu / B+
3)
13 dnu / B−
3)
14
D+
15
dnu / A+
3)
16 dnu / A−
3)
17 D−
PIN
ASSIGNMENT
7
dnu / SP+
4)
8
dnu / B+
3)
9
dnu / SP−
4)
10
0V
3)
11
nE+
12
Ub
3)
21/35