10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Admitted shaft load:
• Materials:
• Corrosion protection:
• Operating temperature:
• Resistance:
• Explosion protection:
• Weight approx.:
• Connection:
MB097c - 11083758
Baumer_HMG11-ETH_II_DE-EN (19A1)
ø122 mm
ø20 mm (through hollow shaft)
IP67
≤3500 rpm (mechanical)
12 Ncm
760 gcm²
≤250 N axial
≤400 N radial
Housing: aluminium alloy
Shaft: stainless steel
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
-20...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
3.5 kg (depending on version)
Bus cover
Terminal box or flange connector M23,
12-pin (SSI/incremental)
10