4.3
Mounting to drive shaft
4.3.1
Blind hollow shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» M inimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
ød (mm)
L1 (mm)
16
53
h6
20
35
h6
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
12�
L2 (mm)
52 (40���52)
34 (25���34)
7b
5
10b
10c
10a
10e
10d
MOUNTING / MOUNTING TO DRIVE SHAFT
7b
10c 10b
10b
9
10c
1�6x8 mm
section 4.5,
L1
L2
DIN 332-D
M6x16 mm
16 mm
17 mm
7a
11b
11a
Mt = 6 Nm
10 mm
TX 20
2
3
5 mm