Baumer HUBNER BERLIN HMG10 Mounting And Operating Instructions - Page 20

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN HMG10. Baumer HUBNER BERLIN HMG10 32 pages. Absolute encoder profinet with magnetic sensing
Also for Baumer HUBNER BERLIN HMG10: Mounting And Operating Instructions (40 pages)

ELECTRICAL CONNECTION / TERMINAL BOX [B]
5.2.5
Switching characteristics speed switch (option)
i
The factory setting of the switching speed for the HMG10P is 6000 rpm� The
HMG10 without programming interface is delivered with the individually ordered
fixed switching speed.
Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
+ns (off) = Switch-off speed at shaft rotation in positive rotating direction*
-ns (off) = Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis
+ns (on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns (on) = Switch-on speed at shaft rotation in negative rotating direction*
* See
section 6, page 20
17/27
-n
-ns (off)
= Speed
: 5...100 % (factory setting = 10 % min. 1 Digit)
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
High resistance (overspeed)
-ns (on)
0
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
+ns (on)
+ns (off)
+n