Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Installation And Operating Instructions Manual
4
Montage / Mounting
4.4

Schritt 3 - Version mit Konuswelle

Motorwelle einfetten!
Die Antriebswelle sollte einen mög-
lichst kleinen Rundlauffehler aufwei-
sen, da dieser zu einem Winkelfehler
führen kann (siehe Abschnitt 4.7).
Außerdem verursachen Rundlauffeh-
ler Vibrationen, die die Lebensdauer
der Kombination verkürzen können.
11
4.4

Step 3 - Cone shaft version

1:10
Lubricate motor shaft!
The drive shaft should have as less
runout as possible because this can
otherwise result in an angle error
(see section 4.7). In addition, any ra-
dial deviation can cause vibrations,
which can shorten the lifetime of the
combination.
Baumer_HOG10-FSL-T2_II_DE-EN (16A2)
Zentrierbohrung
Center hole
DIN 332-D, M6x16 mm
MB071.1T2 - 11069399