Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Installation And Operating Instructions Manual
9.4

Technische Daten - mechanisch

• Baugröße (Flansch):
• Wellenart:
• Zulässige Wellenbelastung:
• Schutzart DIN EN 60529:
• Drehzahl (n):
• Schaltdrehzahlbereich (ns):
• Betriebsdrehmoment typ.:
• Trägheitsmoment Rotor:
• Werkstoff:
• Betriebstemperatur:
• Widerstandsfähigkeit:
• Anschluss:
• Masse ca.:
MB071.1T2 - 11069399
n
ns
´
ns
b)
Prüfbedingungen für Schaltdrehzahl
a)
Drehzahl-Anstieg
b)
Drehzahl-Anstieg
Baumer_HOG10-FSL-T2_II_DE-EN (16A2)
ø105 mm
ø16...20 mm (einseitig offene Hohlwelle)
ø17 mm (Konuswelle 1:10)
≤450 N axial
≤600 N radial
IP66
≤1,25 · ns
850...4500 U/min (Δn = 2 [U/min]/s)
6 Ncm
400 gcm
2
Gehäuse: Aluminium-Druckguss
Welle: Edelstahl
-40...+100 °C
-25...+100 °C (>3072 Impulse pro Umdrehung)
-50...+100 °C (optional mit Heizung)
IEC 60068-2-6:2007
Vibration 5 g, 10-2000 Hz
IEC 60068-2-27:2008
Schock 50 g, 11 ms
2x Klemmenkasten
3x Klemmenkasten (mit Option M)
2,2 kg, 2,4 kg (mit Option M)
a)
t
Δn =
2 [U/min]/s
Δn = 1500 [U/min]/s
9