Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 38

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 40 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
9

Technical data

9
Technical data
9.1

Technical data - electrical ratings

• Interference immunity:
• Emitted interference:
• Approval:
9.2

Technical data - electrical ratings (encoder)

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Output frequency:
• Output signals:
• Output stages:
• Sensing method:
9.3

Technical data - electrical ratings (centrifugal switch)

• Switching accuracy:
• Switching deviation cw-ccw rotation:
• Switching hysteresis:
• Switching outputs:
• Output switching capacity:
• Minimum switching current:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
9)
35
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE
9...30 VDC
(HTL-P, TTL - version R)
9)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
≤120 kHz
≤300 kHz option
K1, K2, K0 + inverted
Error output (option EMS)
HTL-P (power linedriver)
TTL/RS422
(as ordered)
Optical
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
≤3 %
~40 % of switching speed
1 output, speed control
≤6 A / 230 VAC
≤1 A / 125 VDC
50 mA
Baumer_HOG10-FSL-T2_II_DE-EN (17A2)
MB071.1T2 - 11069399