Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
9

Technical data

9
Technical data
9.1

Technical data - electrical ratings

• Interference immunity:
• Emitted interference:
• Approval:
9.2

Technical data - electrical ratings (encoder)

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Output frequency:
• Output signals:
• Output stages:
• Sensing method:
9.3

Technical data - electrical ratings (speed switch)

• Switching accuracy:
• Switching hysteresis:
• Switching delay time:
HOG 10 + ESL 90
• Switching outputs:
• Output switching capacity:
• Minimum switching current:
HOG 10 + ESL 93
• Voltage supply:
• Consumption w/o load:
• Switching outputs:
• Current each output:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
9)
35
EN 61000-6-2
EN 61000-6-3
CE
9...30 VDC
(HTL-P, TTL - version R)
9)
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
≤120 kHz
≤300 kHz option
K1, K2, K0 + inverted
Error output (option EMS)
HTL-P (power linedriver)
TTL/RS422
(as ordered)
Optical
±4 % (≤1500 rpm)
±2 % (>1500 rpm)
≤30 % of switching speed
≤40 ms
1 output, speed control
≤6 A / 250 VAC
≤1 A / 48 VDC
100 mA
12 VDC ±10 %
≤5 mA
3 outputs, speed control
40 mA (DC)
Baumer_HOG10-ESL-T2_II_DE-EN (20A1)