Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
7

Elektrischer Anschluss

7.1

Kabelanschluss

7.1.1
Schritt 1 bis 3
*
13
* Siehe Seite 7 oder 10
See page 7 or 10
Zur Gewährleistung der angegebenen
Schutzart sind nur geeignete Kabel-
durchmesser zu verwenden.
MB136T1 - 11145664
*
12
*
11
14
22 mm
Baumer_HOG10-HOG10G-Harting_T1_DE_EN_202011_MI_11145664 (20A2)
Elektrischer Anschluss / Electrical connection
7

Electrical connection

7.1

Cable connection

7.1.1
Step 1 up to 3
Löt-Crimpkontakte
Solder-crimp contacts
Lötseite
Solder side
*
75 mm
ø7...12 mm
To ensure the specified protection
class of the device the correct cable
diameter must be used.
Ansicht X
siehe Abschnitt 7.4.
View X
see section 7.4.
Kabelschirm
Cable shield
*
26
7
22