10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Shaft insulation:
• Transmission length:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Shaft loading:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Connection:
• Weight approx.:
* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
MB072c - 11141929
Baumer_HOG11-DNV_II_DE-EN (16A2)
9...30 VDC * (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
300...2500 (As ordered)
90° ±20°
30...70 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL-P (power linedriver)
TTL/RS422
(As ordered)
2.8 kV
≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710
DNV approval
ø105 mm
ø16 mm (blind hollow shaft)
≤250 N axial
≤400 N radial
IP67
≤6000 rpm (mechanical)
6 Ncm
340 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
IEC 60068-2-6:2007
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 300 g, 6 ms
Terminal box
1.8 kg
10
Technical data