Baumer HUBNER BERLIN Low Harmonics HOGS 75 Mounting And Operating Instructions - Page 23
Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN Low Harmonics HOGS 75. Baumer HUBNER BERLIN Low Harmonics HOGS 75 24 pages. Sine encoder version with support plate for a torque arm
Also for Baumer HUBNER BERLIN Low Harmonics HOGS 75: Mounting And Operating Instructions (32 pages), Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (36 pages)
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of
SinCos amplitude:
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
MB175bT1 - 11173569
5 VDC ±10 % (version DN ...)
9...26 VDC (version DN ... R)
≤90 mA
1024...2048 (as ordered)
90°
Zero pulse, width 90°
Optical
K1, K2, K0 + inverted
SinCos 1 Vpp
≤20 mV
-50 dB
≤20 mV
200 kHz (-3 dB)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø75 mm
ø12...26 mm (through hollow shaft)
≤80 N axial
≤150 N radial
IP56
≤10000 rpm (mechanical)
≤4 Ncm
180 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-20...+70 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Connecting terminal
580 g
Baumer_HOGS75_T1_DE_EN_202011_MI_11173569 (20A1)
2
10
Technical data
20