6
|
Electrical installation
Ill. 16: Connecting the supply cable
1
3
5
Tools
t20
n
n
Instruction:
a) Loosen the screws at the terminal box.
b) Lift the terminal box off the encoder.
c) Loosen the cable gland at the terminal box.
d) Insert the supply cables into the cable gland, let stick out approx. 50 mm of cable.
e) Assign the supply cables to the terminals.
f) Attach the cable gland to the terminal box.
g) Mount the terminal box at the encoder. For doing so, tighten the screws with a torque of 2-3
Nm.
28
1
5
Terminal connector (wire cross-section
2
≤ 1.5 mm
)
Additional incremental output (optional),
speed switch (optional), programming
interface (PMG10P only)
Terminal box cover
Cable gland M20x1.5 mm (for cable di-
ameter 5-13 mm)
22 mm
Operating Manual
2
3
6
2
Torx / slotted screw M4x32 mm
4
Cable shield
6
Supply cables (cable diameter 5-13
mm)
PMG10 & PMG10P Profibus DP | V1
Baumer Hübner