Baumer Hubner Berlin PMG 10 Installation And Operating Instructions Manual - Page 19

Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer Hubner Berlin PMG 10. Baumer Hubner Berlin PMG 10 36 pages. Absolute encoder with magnetic sensing
Also for Baumer Hubner Berlin PMG 10: Installation And Operating Instructions Manual (48 pages)

Baumer Hubner Berlin PMG 10 Installation And Operating Instructions Manual
5.6
Version with radial terminal boxes
5.6.1
Cable connection
)
To ensure the specified protection of the device the correct cable diameter must
be used�
Connecting cables are not in scope of delivery and can be ordered separately as ac-
cessory, see
Mt = 2-3 Nm
TX 20
13
12
Cable shield
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
ELECTRICAL CONNECTION / VERSION WITH RADIAL TERMINAL BOXES
section 5.8.1, page
14
22 mm
Connecting terminal
first terminal box [ A ].
See
section
22�
15
12
13
14
15
Connecting cable
ø5-13 mm
section 5.6.2.1
or
5.6.2.2�
Terminal box cover
Torx and slotted screw, M4x32 mm
Cable gland M20x1�5 mm
for cable ø5-13 mm
Connecting terminal,
core cross-section ≤1.5 mm
Connecting terminal
second terminal box [ B ].
See
section 5.6.2.3
section
5.6.2.4�
2
or
16/33