8.3
Technical data - mechanical design
Size (flange)
Shaft type
Flange
Protection DIN EN 60529
Operating speed
Schaltdrehzahlbereich
Operating torque typ�
Rotor moment of inertia
Admitted shaft load
Materials
Operating temperature
Relative humidity
Resistance
Corrosion protection
Weight approx�
Connection
MB245EN - 11171693, 17A2, Baumer_PMG10-SSI_II_EN
ø115 mm
ø11 mm solid shaft
EURO flange B10
IP 66/IP 67
≤12000 U/min
±2���12000 rpm,
default 12000 rpm
10 Ncm
1 kgcm
2
≤450 N axial
≤650 N radial
Housing: aluminium alloy
Shaft: stainless steel
-40���+85 °C
95 % non-condensing
IEC 60068-2-6
Vibration 30 g, 10-2000 Hz
IEC 60068-2-27
Shock 400 g, 1 ms
IEC 60068-2-52 Salt mist
Complies to ISO 12944-5:1998
Protective paint systems (C5-M)
1�9 kg (depending on version)
Terminal box
(2x with speed switch/additional output 2)
Flange connector M23
(2x with speed switch/additional output 2)
TECHNICAL DATA
30/33