MOUNTING
4.4
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Encoders should be driven through the Baumer Hübner K 35 spring disk coupling (acces-
sory), that can be pushed onto the shaft without axial loading�
)
The encoder must be mounted on the drive with the least possible angular error
and parallel misalignment�
)
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
Admissible
parallel misalignment
* For insulated hub version
All dimensions in millimeters, unless otherwise stated�
9/21
2-10
Admissible
angular error
MB255EN - 11173976, 16A1, Baumer_PMG10-EtherCAT_II_EN
Admissible
axial movement
±0�7 (±0�3*)