Baumer Hubner Berlin PMG 10 Installation And Operating Instructions Manual - Page 42
Browse online or download pdf Installation And Operating Instructions Manual for Media Converter Baumer Hubner Berlin PMG 10. Baumer Hubner Berlin PMG 10 48 pages. Absolute encoder with magnetic sensing
Also for Baumer Hubner Berlin PMG 10: Installation And Operating Instructions Manual (36 pages)
ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
5.2.5
Cable connection
)
To ensure the specified protection of the device the correct cable diameter must
be used�
Connecting cables are not in scope of delivery�
Cable shield
15/21
12
11
22 mm
MB255EN - 11173976, 16A1, Baumer_PMG10-EtherCAT_II_EN
Mt = 2-3 Nm
TX 20
10
9
9
Terminal box cover
10
Torx and slotted screw,
M4x32 mm
11
Cable gland M20x1�5 mm
for cable ø5-13 mm
12
Connecting terminal,
core cross-section ≤1.5 mm
Connecting cable
ø5-13 mm
Connecting terminal [ B ]
Speed switch/additional output
See
section 5.2.6.1
section
5.2.6.2�
or
2