Cable connection
)
To ensure the specified protection of the device the correct cable diameter must be
used�
Connecting cables are not in scope of delivery and can be ordered separately as accesso-
ry, see
section 6.2, page
M
= 2���3 Nm
t
TX 20
13
12
Cable shield
MB261EN - 11196414, 21A1, Baumer_PMG10-Inc_EN_202103_MI_11196414
25�
14
22 mm
Connecting terminal
first terminal box [A]
ELECTRICAL CONNECTION / CABLE CONNECTION
15
12
13
14
15
Connecting cable
ø5���13 mm
Terminal box cover
Torx/slotted screw M4x32 mm
Cable gland M20x1�5 mm
for cable ø5���13 mm
Connecting terminal,
core cross-section ≤1.5 mm
Connecting terminal
second terminal box [B]