Baumer Hubner Berlin PMG10 Operating Manual - Page 26

Browse online or download pdf Operating Manual for Media Converter Baumer Hubner Berlin PMG10. Baumer Hubner Berlin PMG10 44 pages. Absolute encoder
Also for Baumer Hubner Berlin PMG10: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages)

Baumer Hubner Berlin PMG10 Operating Manual
6
|
Electrical installation
6.8.2

Pin assignment first terminal box

NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
SSI
Programming interface (programmable product variant only)
Additional output incremental 1 (optional)
1
2
3
4
5
6
7
8
Ill. 11: Pin assignment
1
3
5
7
9
11
13
15
I
Programming interface (programmable product variant only)
II
Additional output incremental (optional)
26
I
dnu / SA 
II
dnu / A+ 
II
dnu / B+ 
Ub
nE+
PRE
D+
C+
Operating Manual
9
10
11
12
13
14
15
16
2
dnu / SB 
4
dnu / A− 
6
dnu / B− 
8
0V
10
nE−
12
DIR
14
D−
16
C−
Baumer Hübner
I
II
II
PMG10 & PMG10P SSI | V1