6
|
Electrical installation
6.8.2
Pin assignment first terminal box
NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
SSI
Programming interface (programmable product variant only)
Additional output incremental 1 (optional)
1
2
3
4
5
6
7
8
Ill. 11: Pin assignment
1
3
5
7
9
11
13
15
I
Programming interface (programmable product variant only)
II
Additional output incremental (optional)
26
I
dnu / SA
II
dnu / A+
II
dnu / B+
Ub
nE+
PRE
D+
C+
Operating Manual
9
10
11
12
13
14
15
16
2
dnu / SB
4
dnu / A−
6
dnu / B−
8
0V
10
nE−
12
DIR
14
D−
16
C−
Baumer Hübner
I
II
II
PMG10 & PMG10P SSI | V1