Baumer Hübner
6.9.2
Assignment first flange connector
NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
SSI
Programming interface (HMG10P only)
Additional output incremental 1 (optional)
10
9
8
Ill. 13: Flange socket M23 (male, 17-pin, clockwise)
PIN
1
2
3
4
5
6
7
8
9
I
Programming interface (programmable product variant only)
II
Additional output incremental (optional)
V1 | PMG10 & PMG10P SSI
1
11
2
12
13
16
3
15
14
4
17
5
6
7
Assignment
nE−
DIR
dnu / SB
nE+
PRE
dnu / SA
Ub
C+
C−
PIN
10
11
I
12
13
14
I
15
16
17
Operating Manual
Electrical installation
|
6
Assignment
0V
Internal shield
II
dnu / B+
II
dnu / B−
D+
II
dnu / A+
II
dnu / A−
D−
29