Baumer HUBNER BERLIN PROFI NET microGen HMG10 Mounting And Operating Instructions - Page 13

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN PROFI NET microGen HMG10. Baumer HUBNER BERLIN PROFI NET microGen HMG10 32 pages. Absolute encoder profinet with magnetic sensing

4.3.3
Through hollow shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» M inimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
>113 mm
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
12�
ød (mm)
16
h6
20
h6
10b
10c
MOUNTING / MOUNTING TO DRIVE SHAFT
Loosen the screw
8b
5
10a
10c
10e
10b
10d
1�6x8 mm
Tighten the screw
Mt = 2���3 Nm
section 4.5,
TX 10
8c
9
10b
10c
10 mm
10/27