Baumer HUBNER BERLIN PROFI NET microGen HMG10 Mounting And Operating Instructions - Page 22
Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN PROFI NET microGen HMG10. Baumer HUBNER BERLIN PROFI NET microGen HMG10 32 pages. Absolute encoder profinet with magnetic sensing
ELECTRICAL CONNECTION
5.2.7
Assignment connecting terminal
)
Do not connect voltage supply to outputs! Danger of damage!
Please, beware of possible voltage drop in long cable leads (inputs and out-
puts)!
)
The TTL/HTL (Vin = Vout) output at the additional output incremental is electri-
cally isolated and requires a separate power supply�
dnu / SP+
dnu / A+
dnu / A
dnu / B+
dnu / B
Additional output incremental (option)
3)
Speed switch (option)
4)
Programming interface (only HMG10P)
5)
5.3
Accessory Z-PA.SDL.1 WLAN adapter: Programming device for HMG10P
The Z-PA�SDL�1 WLAN adapter is a programming device for programming and monitoring
HMG10P/PMG10P series encoders�
The following encoder parameters can be parameterized (depending on the version of the
encoder):
• Additional output 1 and 2 (number of pulses per revolution)
• Switch-off and switch-on speeds
The programming device can be configured and operated via a web browser.
i
A detailed description of all available functions can be find in the mounting and ope-
rating instructions of the WLAN adapter�
Z-PA�SDL�1 WLAN adapter
19/27
4)
3)
_
3)
3)
_
3)
Ub
3)
0V
3)
dnu / SP-
nE+
nE _
dnu / R+
_
dnu / R
dnu / SA
dnu / SB
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
4)
3)
3)
5)
5)
Part number
11190106