Baumer HUBNER BERLIN PROFI NET microGen HMG10P Mounting And Operating Instructions - Page 26

Browse online or download pdf Mounting And Operating Instructions for Media Converter Baumer HUBNER BERLIN PROFI NET microGen HMG10P. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 40 pages. Incremental encoder with magnetic sensing
Also for Baumer HUBNER BERLIN PROFI NET microGen HMG10P: Mounting And Operating Instructions (32 pages), Operating Manual (44 pages)

Baumer HUBNER BERLIN PROFI NET microGen HMG10P Mounting And Operating Instructions
ELECTRICAL CONNECTION / ASSIGNMENT FLANGE CONNECTOR M23
1x flange connector M23 - View B (see dimensions)
Speed switch (connection reference -H)
Pin
Assignment
1
dnu
2
SB
3
dnu
4
dnu
5
dnu
6
dnu
7
SP+
8
dnu
9
SP-
10
0 V
11
SA
12
Ub
2x flange connector M23 - View B / A (see dimensions)
Incremental output II / Incremental output I (connection reference -L)
Pin
View B/Inc.-outp. II
1
B-
2
dnu
3
R+
4
R-
5
A+
6
A-
7
dnu
8
B+
9
dnu
10
0 V
11
dnu
12
dnu
26/40
8
1
9
10
12
2
7
3
6
11
4
5
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
8
1
9
10
12
2
7
3
6
11
4
5
Pin
View A/Inc.-outp. I
1
B-
2
dnu
3
R+
4
R-
5
A+
6
A-
7
SA
8
B+
9
SB
10
0 V
11
dnu
12
Ub
8
1
9
10
12
7
6
11
4
5
2