Baumer HUBNER BERLIN PROFI NET microGen HMG10P Operating Manual - Page 24

Browse online or download pdf Operating Manual for Media Converter Baumer HUBNER BERLIN PROFI NET microGen HMG10P. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 44 pages. Incremental encoder with magnetic sensing
Also for Baumer HUBNER BERLIN PROFI NET microGen HMG10P: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (40 pages)

Baumer HUBNER BERLIN PROFI NET microGen HMG10P Operating Manual
5
|
Installation
5.7

Avoiding and calculating angular errors

INFO
For further information, please call the telephone hotline at +49 (0)30 69003-111.
Instruction:
a) Make sure that concentricity errors of the drive shaft do not exceed 0.2 mm (0.03 mm rec-
ommended) to prevent angular errors.
b) Limit such angular errors by increased gap L1. For doing so, various torque plates for are
available on request.
c) Note that length L2 of the torque arm should be ≥ L1. Where not possible, consider L2.
d) To calculate angular errors Δp
tical gap of torque arm towards the device center in mm):
Δp
mech
Calculation example:
With R= 0.06 mm and L1 = 69.5 mm, the angular error Δp
24
 = ±90°/π × R/L1
Operating Manual
L1
proceed as follows ( R = runout error in mm and L1 = ver-
mech
HMG10 & HMG10P EtherNet/IP | V1, T1
Baumer Hübner
is ±0.025°.
mech