10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude:
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approval:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Ambient temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB051a - 11102670
Baumer_EEXOG9S_II_DE-EN (19A2)
5 VDC ±5 % (version DN ...)
9...30 VDC (version DN ... R)
≤90 mA
1024...2048 (as ordered)
90°
Zero pulse, width 90°
Optical
K1, K2, K0 + inverted
SinCos 1 Vpp
≤20 mV
-50 dB
≤20 mV
250 kHz (-3 dB)
EN 61000-6-2
EN 61000-6-3
CE
ø115 mm
ø11 mm solid shaft
≤200 N axial
≤350 N radial
EURO flange B10
IP56
≤6000 rpm (T5, mechanical)
≤4500 rpm (T6, mechanical)
4 Ncm
290 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-20...+55 °C
IEC 60068-2-6
Vibration 10 g, 50-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 2 G Ex db eb IIC T5/T6 Gb
Ex db eb IIC T5/T6 Gb
Terminal box
3.5 kg
10
Technical data
24