ELECTRICAL CONNECTION / ELECTRICAL CONNECTION WITH RADIAL FLANGE CONNECTORS
5.8

Electrical connection with radial flange connectors

5.8.1
Cable connection mating connector M23 (accessory)
)
To ensure the specified protection of the device the correct cable diameter must
be used�
Connecting cables and mating connectors are not in scope of delivery and can be
ordered separately as accessory, see
EMC ring
Connecting cable ø7���12 mm
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
Cable shield
27 mm
Mating connector M23
section 6.2, page
Second
flange connector [D]
See
section 5.8.2.2
Code
24 mm
23�
First
flange connector [C]
See
section 5.8.2.1
Hand-tight