Also for Baumer PMG10P: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (32 pages), Operating Manual (44 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (36 pages)

Baumer PMG10P Operating Manual
6
|
Electrical installation
6.3

Output signals additional incremental output (optional)

At positive rotating direction
A+
A-
B+
B-
R+
Zero pulse+
R-
Zero pulse-
Ill. 9: Output signals with positive direction of rotation (zero pulse R+ and R- are only available at additional
output II)
6.4

Switching level additional output incremental (optional)

Switching level
High/Low
Transmission length
Output frequency
I
The TTL/HTL output (Vin = Vout) at the additional output II incremental is galvanically iso-
lated and requires a separate voltage supply.
Tab. 1: Switching level additional output incremental (optional)
6.5

Programming interface (only for programmable variant)

Encoder parameters such as resolution singleturn and/or multiturn (SSI), binary or gray code
(SSI), additional output 1 and 2, switch-off and switch-on speeds can be changed and read out
via connection SA and SB. The Z-PA.SDL.1 WLAN adapter can be used to access the encoder
via web browser.
22
90°
TTL/RS422
≥ 2,5 V / ≤ 0,5 V
≤ 550 m bei 100 kHz
≤ 600 kHz
Operating Manual
Baumer Hübner
TTL/HTL (Vin = Vout)
≥ 2,5 V / ≤ 0,5 V (TTL)
n
≥ Ub − 3 V / ≤ 1,5 V (HTL)
n
≤ 550 m bei 100 kHz (TTL)
n
≤ 350 m bei 100 kHz (HTL)
n
≤ 600 kHz (TTL)
n
≤ 350 kHz (HTL)
n
PMG10 & PMG10P SSI | V1
I