Baumer PMG10P Operating Manual - Page 30

Browse online or download pdf Operating Manual for Media Converter Baumer PMG10P. Baumer PMG10P 44 pages. Absolute encoder
Also for Baumer PMG10P: Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (32 pages), Operating Manual (44 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (40 pages), Operating Manual (36 pages)

Baumer PMG10P Operating Manual
6
|
Electrical installation
6.9.3

Assignment second flange connector

NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
Additional incremental output 2 (optional)
Speed switch (optional)
The TTL/HTL output (Vin = Vout) at the additional incremental output 2 is galvanically isolated
and requires separate voltage supply.
7
6
Ill. 14: Flange socket M23 (male, 12-pin, clockwise)
PIN
1
2
3
4
5
6
I
Additional output incremental (optional)
II
Speed switch (optional)
30
8
1
9
10
12
2
3
11
4
5
Assignment
dnu / B−
I
nE− 
dnu / R+
dnu / R−
dnu / A+
dnu / A−
Operating Manual
PIN
I
7
8
I
9
I
10
I
11
I
12
Baumer Hübner
Assignment
II
dnu / SP+
I
dnu / B+
II
dnu / SP−
I
0V
I
nE+ 
I
Ub 3)
PMG10 & PMG10P SSI | V1