Baumer FVDK 10P66Y0 Quick Start Manual - Page 6
Browse online or download pdf Quick Start Manual for Security Sensors Baumer FVDK 10P66Y0. Baumer FVDK 10P66Y0 8 pages. Fiber optic sensor
4.3 Incoming light level display
Press
AUTO
OK
Indication
Displ ay
type
( green)
Menu
Normal
Preset value
display
AUTO
Stability safety
OK
margin
P *
indication
Press
When the stability safety margin is indicated, "P" is always displayed.
Two methods of displaying incoming light level on the digital display
can be selected.
Normal display (initial mode): Displays the current incoming light
level (red) and the set value (green)
Stability safety margin indication: The letter P (green) and the ratio
(in %) if the incoming light level (red) to the detection threshold are
displayed.
4.4 Monitor sleep mode
Press
AUTO
OK
Disa ble monitor sleep
Ena ble monitor sleep
AUTO
OK
Press
The current consumption can be decreased about 30% if the display
will be turned off. A green moving point in the display shows that the
sensor is still working in normal operation.
If using the display-off function, the display changes to energy
saving mode after 20 seconds.
4.5 Display inversion
Press
AUTO
OK
Do not i nvert
Invert
AUTO
OK
Press
4.6 Self threshold adjustment STA
This function automatically adjusts the detection threshold using a
given ratio of the threshold to the incoming light level. The auto-
adjustment of the threshold is carried out at regular intervals
Displ ay
(approx. every 3 s). When STA is enabled, the STA indicator is lit. If
(red)
+
Incoming
the threshold is not adjusted due to the incoming light level fall in
light level
below the limit, the indicator blinks. When STA is enabled, neither
Stability
manual tuning nor auto-tuning is possible. If STA will be used, check
safety
–
its operation in advanced. If the incoming Light level fluctuates due
margin
to a combination of the sensor and a diffuse scan fiber unit or a slow
work piece speed, STA may fail to adjust the threshold to the
expected one.
Press
AUTO
OK
When STA is
disabled
AUTO
OK
Setting of
the STA rate
Press
+
*Between 50 and 95 P, STA can be set in increments of 5 P.
–
4.7 Option
Press
AUTO
OK
AUTO
OK
Press
+
Option settings allow a combination of automatic sensitivity
switching saving to EEPROM and enabling/disabling STA reset.
EEPROM storage: Settings modified by STA are stored in
–
EEPROM. When the function is enabled settings are stored in
EEPROM. When function is disabled settings are not stored in
EEPROM. If writing to EEPROM would be very frequent, select
"disabled" (durability: approx. 200'000 erase-write cycles).
+
Timer types
STA is disabled
STA is enabled
AUTO
–
OK
When STA is enabled
+
AUTO
OK
–
Automatic
STA
sensitivity
reset upon
EEPROM
switching
power-up
Storage
Menu
+
–
4.8 Emitter frequency switching
Press
AUTO
OK
+
AUTO
–
OK
Response times for Fr-2 di er from those for Fr-1.
Press
The emitter LED frequency can be selected from Fr-1 and Fr-2
(when "normal" or "semi fast" is selected). Even if fiber units are next
to each other, mutual interferences can be prevented for up to 2
units by selecting different frequencies.
4.9 Factory setup
Press
AUTO
OK
Do not initiali ze
Initialize
AUTO
OK
Press
Do not initiali ze
Initialize
Retu rn to normal ope ration after initialization
+
–
6/8