Baumer 27029 Installation And Operating Instructions Manual - Page 28

Browse online or download pdf Installation And Operating Instructions Manual for Measuring Instruments Baumer 27029. Baumer 27029 32 pages. Tachogenerator with integrated encoder

Baumer 27029 Installation And Operating Instructions Manual
11

Technical data

11
Technical data
11.1

Technical data - electrical ratings

Interference immunity:
Emitted interference:
Approvals:
11.2

Technical data - electrical ratings (tachogenerator)

Reversal tolerance:
Linearity tolerance:
Temperature coefficient:
Isolation class:
Calibration tolerance:
Climatic test:
TDP 0,2 + OG 9
Performance:
Armature-circuit time-constant (τ
Open-circuit voltage:
TDPZ 0,2 + OG 9
Performance:
Armature-circuit time-constant (τ
Open-circuit voltage:
11.3

Technical data - electrical ratings (encoder)

Voltage supply:
Consumption w/o load:
Pulses per revolution:
Phase shift:
Scan ratio:
Reference signal:
Sensing method:
Output frequency:
Output signals:
Output stages:
11.4

Technical data - mechanical design

Dimensions (flange):
Shaft type:
Shaft loading:
Flange:
Protection DIN EN 60529:
Speed (n):
Torque:
Materials:
Operating temperature:
Resistance:
Connection:
25
):
A
):
A
Baumer_TDP02-OG9-TDPZ02-OG9_II_DE-EN (14A1)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, RoHS
≤0.1%
≤0.15%
±0.05%/K
B
±1 %
Humid heat, constant (IEC 60068-2-3, Ca)
12 W (speed >3000 rpm)
<75 µs
10...150 mV per rpm
2x 3 W (speed >3000 rpm)
<40 µs
20...100 mV per rpm
5 VDC ±5 % / 9...26 VDC
9...30 VDC
≤100 mA
1...1250
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
TTL/RS422 / HTL-P (power linedriver)
ø115 mm
ø11 mm solid shaft (Option: ø14 mm solid shaft)
≤60 N axial, ≤80 N radial
EURO flange B10
IP 55 (Option: IP 56)
≤10000 rpm
1.5 Ncm
Housing: aluminium die-cast, Shaft: stainless steel
-30...+100°C
IEC 60068-2-6:2007:
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008:
Shock 100 g, 6 ms
2x terminal box
MB079.3 - 11130053