6.2
Power supply of the encoder
The encoder power is supplied either from the HENQ 1100 (
from the frequency inverter or the control system (
The selection is made in menu
6.2.1
Encoder supply from the HENQ 1100
6.2.2
External power supply for the encoder
MB112EN - 11185046, 19A1, Baumer_HENQ1100_OI_EN
U
= UB - 1 V or U
1
2
(opionally: RS232)
USB ⇔ RS485
U
= U
or U
= U
1
REG1
2
(opionally: RS232)
CONNECTIONS / POWER SUPPLy OF THE ENCODER
EXT ), see
INT / EXT , see
, menu item
= 5 V
RS485
REG2
RS485
INT ), see
section
section
6.2.2�
Fig.3, page
16�
Power supply
UB = 9���30 V
Measured values
displayed on the
PC, see
page
U
= 9...30 V or U
REG1
Controller
Power supply
UB = 9���30 V
USB ⇔ RS485
Measured values displayed on
the PC, see
section 8, page
24�
6.2.1, or
section 8,
24�
= 5 V
REG2
10/32