Baumer OM30 Operating Manual - Page 45

Browse online or download pdf Operating Manual for Measuring Instruments Baumer OM30. Baumer OM30 48 pages. Laser distance sensors

Baumer OM30 Operating Manual
Baumer
11

Troubleshooting

Error:
n
Sensor does not start even though the power supply is connected. The LEDs of the sensor
are switched off.
Possible cause:
n
The power supply is interrupted. A short-circuit is present.
Remedy:
n
Check the electrical connection of the sensor according to the connection diagram.
Error:
n
No valid measured value can be recorded, the LED lights up yellow, and the laser is
switched on.
Possible cause:
n
The measurement object is outside of the measurement range (MR). The measurement
range for your sensor version can be found in the data sheet.
Remedy:
n
Move the measurement object into the measurement range.
Error:
n
The measurement results are incorrect.
Possible cause:
n
The direct reflection of the laser hits the receiver of the sensor. This happens especially with
shiny surfaces.
Remedy:
n
Tilt the sensor to the side so that the direct reflection of the laser does not hit the receiver of
the sensor.
Error:
n
The measured value shows faulty, erratic behavior.
Possible cause:
n
Too much ambient light enters the field of view of the sensor receiver. This leads to disturb-
ing peaks on the receiver.
Remedy:
n
Reduce the ambient light (e. g. with a cover).
11.1

Return and repair

In case of complaints, please contact the relevant sales unit.
11.2

Accessories

You can find accessories on the website at:
https://www.baumer.com
OM20/OM30 | V1
Operating Manual
Troubleshooting
|
11
45