Baumer R600V.RAH5-11225384 User Manual
Browse online or download pdf User Manual for Measuring Instruments Baumer R600V.RAH5-11225384. Baumer R600V.RAH5-11225384 4 pages. Radar retro-reflective sensor
Radar Sensoren
Radar sensors
Détecteurs à radar
R600V.RAH5-11225384
Radar Reflextaster
Radar retro-reflective sensor
Détecteur à réflexion radar
1/4
Abmessungen
Dimensions
Dimensions
82
62
97
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Erfassungsbereich Sd
0,3 ... 8,5 m
Öffnungswinkel
6° (3dB)
Betriebsspannungsbereich
9 ... 32 VDC
+Vs
Stromaufnahme max.
160 mA
(ohne Last)
Ausgangsschaltung
CAN (5V)
logische Schnittstelle
CAN SAE J1939
Baud Rate
250 kBaud (500 kBaud)
kurzschlussfest
ja
verpolungsfest
ja, Vs zu GND
Arbeitstemperatur
-40 ... +70 °C
Lagertemperatur
-40 ... +85 °C
Schutzart
IP 68/69K
Technische Änderungen vorbehalten
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTICE: Changes or modifications made to this equipment not expressly approved by Baumer may void the FCC authorization
to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not in-
stalled and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Radiofrequency radiation exposure Information: This equipment complies with FCC exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Elektrischer Anschluss
42
(1)
(2)
CAN SAE
(4)
J1939
(3)
32
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
sensing distance Sd
0,3 ... 8,5 m
aperture angle
6° (3dB)
voltage supply range
9 ... 32 VDC
+Vs
current consumption
160 mA
max. (no load)
output circuit
CAN (5V)
logical interface
CAN SAE J1939
baud rate
250 kBaud (500 kBaud)
short circuit protection
yes
reverse polarity pro-
yes, Vs to GND
tection
operating temperature
-40 ... +70 °C
storage temperature
-40 ... +85 °C
protection class
IP 68/69K
Tecnical specifications subject to change
Canada Compliance Statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two condi-
tions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. This equipment complies with IC radiation exposure limits set forth for an un-
controlled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator
and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploita-
tion est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Cet équipement
est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit
être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Ce transmetteur
ne doit pas etre place au meme endroit ou utilise simultanement avec un autre transmetteur ou antenne.
Connection diagram
Schéma de raccordement
+Vs
CAN HI
CAN LO
0 V
Données techniques
Portée de détection Sd
Angle d'ouverture
Plage de tension +Vs
Consommation max.
(sans charge)
circuit de sortie
interface logique
vitesse de transmission
Protégé contre
courts-circuits
Protégé contre inversion
polarité
Température de foncti-
onnement
Température de stocka-
ge
Classe de protection
Sous réserve de modifications techniques
2 CAN HI
4 CAN LO
3 GND
1 +Vs
0,3 ... 8,5 m
6° (3dB)
9 ... 32 VDC
160 mA
CAN (5V)
CAN SAE J1939
250 kBaud (500 kBaud)
oui
oui, Vs vers GND
-40 ... +70 °C
-40 ... +85 °C
IP 68/69K