Baumer APY Mounting And Operating Instructions - Page 23
Browse online or download pdf Mounting And Operating Instructions for Portable Generator Baumer APY. Baumer APY 26 pages. Longlife dc tachgenerator with py flange
9.3
Type data
voltage
Type
[mV/rpm]
APY 20
APY 50
APY 100
Superimposed ripple (for τ
9.4
Replacement switching diagram
Polarity for positive direction of rotation:
A1: +
R
L
A
A
U
(n)
0
Tachogenerator
τ
≈ R · C
τ
RC
A
MB038 - 11055641
Open-
Minimum load required
circuit
depending on speed range
(DC)
0 - 3000:
U
R
0
L
[kΩ]
20
≥0.3
50
≥1.9
100
≥7.5
= 0.7 ms): ≤0.5% peak-peak (≤0.2% rms)
RC
A2: -
(VDE)
R
A1
U(n)
R
C
L
A2
L
A
≈
R
L
Baumer_APY_DE_EN_202309_MI_11055641 (23A1)
[rpm]
0 - 6000:
0 - n
:
max
R
R
L
L
[kΩ]
[kΩ]
≥1.2
≥3.3
≥7.8
≥21.5
≥30
≥30
U(n) = U
(n)
R
0
A
Technical data
Maximum
Armature
operating
resistance
speed
n
R
(20°C)
max
A
[rpm]
[Ω]
10000
11
10000
66
6000
271
U(n)
-n
-U(n)
R
L
≈ U
(n) for R > R
+ R
0
L
9
Armature
inductance
L
A
[mH]
23
137
546
n
>> R
L
A
20