Baumer Hubner Berlin TDP0,2LS-5 Installation And Operating Instructions Manual - Page 28
Browse online or download pdf Installation And Operating Instructions Manual for Portable Generator Baumer Hubner Berlin TDP0,2LS-5. Baumer Hubner Berlin TDP0,2LS-5 32 pages. Tachogenerator with integrated centrifugal switch
Also for Baumer Hubner Berlin TDP0,2LS-5: Installation And Operating Instructions Manual (28 pages)
10
Technical data
10
Technical data
10.1
Technical data - electrical ratings
Interference immunity:
•
Emitted interference:
•
Approval:
•
10.2
Technical data - electrical ratings (tachogenerator)
Reversal tolerance:
•
Linearity tolerance:
•
Temperature coefficient:
•
Isolation class:
•
Calibration tolerance:
•
Climatic test:
•
TDP 0,2 + FSL
Performance:
•
Armature-circuit time-constant (τ
•
Open-circuit voltage:
•
TDPZ 0,2 + FSL
Performance:
•
Armature-circuit time-constant (τ
•
Open-circuit voltage:
•
10.3
Technical data - electrical ratings (centrifugal switch)
Switching accuracy:
•
Switching deviation cw-ccw rotation: ≤3 %
•
Switching hysteresis:
•
Switching outputs:
•
Output switching capacity:
•
10.4
Technical data - mechanical design
Size (flange):
•
Shaft type:
•
Shaft loading:
•
Flange:
•
Protection DIN EN 60529:
•
Speed (n):
•
Range of switching speed (ns):
•
Torque:
•
Materials:
•
Operating temperature:
•
Resistance:
•
Connection:
•
TDP 0,2 + FSL
Rotor moment of inertia:
•
Weight approx.:
•
TDPZ 0,2 + FSL
Rotor moment of inertia:
•
Weight approx.:
•
25
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE
≤0.1 %
≤0.15 %
±0.05 %/K
B
±1 %
Humid heat, constant (IEC 60068-2-3, Ca)
12 W (speed >3000 rpm)
):
<75 µs
A
10...150 mV per rpm
2x 3 W (speed >3000 rpm)
):
<40 µs
A
20...100 mV per rpm
±4 % (Δn = 2 rpm/s); ≥ +20 % (Δn = 1500 rpm/s)
~40 % of switching speed
1 output, speed control
≤6 A / 230 VAC; ≤1 A / 125 VDC
ø115 mm
ø11 mm solid shaft (Option: ø14 mm solid shaft)
≤60 N axial; ≤80 N radial
EURO flange B10
IP55 (option: IP56)
≤1.25 · ns
850...4500 rpm (Δn = 2 rpm/s)
1.5 Ncm
Housing: aluminium die-cast; Shaft: stainless steel
-30...+130 °C
IEC 60068-2-6:2007: Vibration 5 g, 10-2000 Hz
IEC 60068-2-27:2008: Shock 150 g, 1 ms
2x terminal box
1.4 kgcm²
3.1 kg
1.5 kgcm²
3.5 kg
Baumer_TDP02-FSL-TDPZ02-FSL_II_DE-EN (15A3)
MB079.1 - 11115288