10
Technical data
10
Technical data
10.1
Technical data - electrical ratings
• Reversal tolerance:
• Linearity tolerance:
• Temperature coefficient:
• Isolation class:
• Climatic test:
• Interference immunity:
• Emitted interference:
TDP 0,2
• Calibration tolerance:
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
TDPZ 0,2
• Calibration tolerance:
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
10.2
Technical data - mechanical design
• Dimensions (flange):
• Shaft type:
• Protection DIN EN 60529:
• Torque:
• Shaft loading:
• Materials:
• Operating temperature:
• Resistance:
• Connection:
TDP 0,2
• Rotor moment of inertia:
• Weight approx.:
TDPZ 0,2
• Rotor moment of inertia:
• Weight approx.:
23
≤0.1 %
≤0.15 %
±0.05 %/K
B
Humid heat, constant (IEC 60068-2-3, Ca)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
±1 %
12 W (speed >3000 rpm)
):
<75 µs
A
10...150 mV per rpm
±1 %
2x 3 W
):
<40 µs
A
20...100 mV per rpm
ø105 mm
ø11 mm solid shaft (option: ø7 mm, ø14 mm)
IP55 (option: IP56)
1.5 Ncm
≤60 N axial
≤80 N radial
Housing: aluminium die-cast
Shaft: stainless steel
-30...+130 °C
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 300 g, 1 ms
Terminal box
1.1 kgcm²
2,6 kg
1.2 kgcm²
3.0 kg
Baumer_TDP02-TDPZ02-B3_II_DE-EN (16A2)