Also for Baumer HUBNER TDP 0,2 Series: Installation And Operating Instructions Manual (32 pages), Installation And Operating Instructions Manual (32 pages), Mounting And Operating Instruction (28 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER TDP 0,2 Series Installation And Operating Instructions Manual
4.5
Hinweis bei Verwendung einer Klauen-
kupplung (zum Beispiel „ROTEX®")
Eine falsche Montage der Klauenkupplung
führt zur Beschädigung des Tachogenera-
tors.
Den korrekten Abstand der beiden Kupp-
lungshälften, siehe unten, einhalten.
Eine Blockung der beiden Kupplungs-
hälften (Klauen liegen Stirn auf Stirn)
ist zu vermeiden.
Es darf kein direkter Axialschlag auf
die Tachogeneratorwelle erfolgen.
MB079a - 11068397
Baumer_TDP02-TDPZ02-B3_II_DE-EN (16A2)
4.5
Note when using a jaw-type coupling
(for example "ROTEX®")
Incorrect mounting of the jaw-type cou-
pling can damage the tachogenerator.
Observe the correct distance of both cou-
pling halves, see below.
1-2 mm
Avoid blocking of both coupling
halves (claws pressed together).
The tachogenerator shaft must not
subjected to direct axial shock.