Also for Baumer HUBNER TDP 0,2 Series: Installation And Operating Instructions Manual (32 pages), Installation And Operating Instructions Manual (32 pages), Installation And Operating Instructions Manual (28 pages), Mounting And Operating Instruction (28 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER TDP 0,2 Series Mounting And Operating Instructions
4.3.2

Schritt 3

Anzugsmoment:
Tightening torque:
M
= 1.3 ±10 % Nm
t
2.5 mm
10 mm
* Siehe Seite 5 oder 7
See page 5 or 7
4.4

Montagehinweis

i
Wir empfehlen, das Gerät so zu
montieren, dass der Kabelanschluss
keinem direkten Wassereintritt
ausgesetzt ist.
MB079.2 - 11115290
*
15
*
*
18
19
5
Baumer_TDP02-ESL-TDPZ02-ESL_II_DE-EN (20A1)
4.3.2

Step 3

*
4.4

Mounting instruction

i
It is recommended to mount the device
with cable connection facing down-
ward and being not exposed to water.
Montage / Mounting
4
10