Baumer HUBNER TDP 0,2 Series Mounting And Operating Instructions - Page 20

Browse online or download pdf Mounting And Operating Instructions for Portable Generator Baumer HUBNER TDP 0,2 Series. Baumer HUBNER TDP 0,2 Series 32 pages. Tachogenerator (doppel-tachogenerator), tachogenerator (twin tachogenerator)
Also for Baumer HUBNER TDP 0,2 Series: Installation And Operating Instructions Manual (32 pages), Installation And Operating Instructions Manual (32 pages), Installation And Operating Instructions Manual (28 pages), Mounting And Operating Instruction (28 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER TDP 0,2 Series Mounting And Operating Instructions
6
Elektrischer Anschluss / Electrical connection
6.2
ESL
6.2.2
ESL 90
(1 internes Relais, 1 Schaltdrehzahl)
6.2.2.1
Anschlussbelegung
Ansicht Y
Anschlussklemmen,
siehe Abschnitt 6.2.1.
View Y
Connecting terminal,
see section 6.2.1.
6.2.2.2
Blockschaltbild
G
3~
n s
ESL 90
6.2.2.3
Ausgangsschaltverhalten
closed 2-3
open
-n
n = Drehzahl/Speed
ns = Eingestellte Schaltdrehzahl / Adjusted switching speed
17
COMP
closed 1-2
1-2
open
-ns
0
Baumer_TDP02-ESL-TDPZ02-ESL_II_DE-EN (20A1)
6.2
ESL
6.2.2
ESL 90
(1 internal relay, 1 switching speed)
6.2.2.1
Terminal assignment
≤6A / 250 VAC
≤1A / 48 VDC
6.2.2.2
Block circuit diagram
=
=
6.2.2.3
Switching characteristics
closed 2-3
2-3
open
+ns
1
3
2
1-2
+n
MB079.2 - 11115290