5.

Mechanical Mounting

5.1. Preparations
• Attention! Observe the safety instructions in chapter 4.
• Make sure the drive will not be operational for the time of tachogenerator

installation.

• Prior to any installation work, switch off overall voltage supply and ensure
machinery is idle..
• We recommend sufficient contact surface according to the dimensions specified in
chapter 8. For tachogenerator type identification see product label.
5.2. Installation
• Make sure the necessary preparations for installation according to
chapter 5.1. are present.
5.2.1. Shaft designs: KTD 3-... B10; KTD 3-... + ITD 2... B10;
ITD 4.... + KTD 3-... B10...
• Avoid a rigid connection between tachogenerator and drive shaft.
• Connect drive and tachogenerator shaft using a suitable coupling.
The tachogenerator must be mounted on the drive with the least possible angular
error and parallel misalignment.
• For suitable connections, see accessories.
• Ensure correct installation without hampering operation.
• Objects in the near vicinity must be kept at a sufficient distance from the
coupling.
flexible,
torsionally rigid
coupling CPS...
Baumer_KTD3A4-KTD3B10-KTD3-Kombinationen_OI_DE-EN_1606.indd
fixings
screws
13