8.
Dimensional drawings
KTD 4-... A 4
mounting side
(proposition)
feather key
DIN 6885 - A
18
30
2.5
4
d= ø10 - ø16 mm
Please specify the desired
bore diameter in your order.
hub keyway according to DIN 6885 - tight fit P9
KTD 4-... A 4 Y 5
mounting side
(proposition)
30
2.5
4
Baumer_KTD4A4_OI_DE-EN_1606.indd
A
0.02 A
A
0.02
A
Type
VDC
b
KTD 4-1 A 4 Y 5
10
33.5
KTD 4-2 A 4 Y 5
20
33.5
KTD 4-3 A 4 Y 5
30
33.5
KTD 4-4 A 4 Y 5
40
33.5
60
KTD 4-6 A 4 Y 5
43.5
ground terminal M4
ring clamping element
cylinder head screw
DIN EN ISO 4762
- M4x16
Type
2
KTD 4-1 A 4
KTD 4-2 A 4
KTD 4-3 A 4
KTD 4-4 A 4
ring clamping
pressure screw
element
A/F22
c
c
44
44
44
d = ø10 - ø16 mm
44
Please specify the desired
54
bore diameter in your order.
ø86
d H7
VDC
10
20
30
40
88
ground
terminal M4
d H7
2
019- 3
019- 3 Y 5
13