Resending of lost pack-
ets at the end of the
data stream.
32
In our example, packets from no. 3 to no. 5 are lost. This fault is detected after the
predefined time has elapsed and the resend request (A) is triggered. The camera then
resends packets no. 3 to no. 5 (B) to complete the image transfer.
5.5.4.
Termination Conditions
The resend mechanism will continue until:
▪
all packets have reached the pc
▪
the maximum of resend repetitions is reached
▪
the resend timeout has occured or
▪
the camera returns an error.