Baumer EXG50c User Manual - Page 12

Browse online or download pdf User Manual for Digital Camera Baumer EXG50c. Baumer EXG50c 42 pages. Gigabit ethernet

Baumer EXG50c User Manual
Figure 8 ►
Temperature measure-
ment points of Baumer 
EXG cameras
12
Environmental Requirements
2.4
2.4.1 Temperature and Humidity Range
Storage temperature
Operating temperature*
Housing temperature
**)***)
* For environmental temperatures ranging from (value A) to (value B), please pay atten-
tion to the max. housing temperature. The values are listed in the table below:
Camera Type
Monochrome
EXG03
EXG50
Color
EXG03c
Storage and Operating Humidity
2.4.2 Heat Transmission
It is very important to provide adequate dissipation of heat, to ensure that the temperature 
does not reach or exceed +50°C (+122°F). As there are numerous possibilities for instal-
lation, Baumer do not specifiy a specific method for proper heat dissipation, but suggest 
the following principles:
▪ operate the cameras only in mounted condition
▪ mounting in combination with forced convection may provide proper heat dissipation
*) 
Please refer to the respective data sheet.
**) 
Measured at temperature measurement point (T).
***) 
Housing temperature is limited by sensor specifications.
*)
Temperature
-10°C ... +70°C ( +14°F ... +158°F)
+5°C ... +50°C (+41°F ... +122°F)
max. +50°C (+122°F)
Value A
+25°C (+77°F)
+25°C (+77°F)
+25°C (+77°F)
Humidity
Non-condensing
T
Value B
+50°C (+122°F)
+50°C (+122°F)
+50°C (+122°F)
10% ��� 90%