Baumer SXC20 User Manual - Page 42
Browse online or download pdf User Manual for Digital Camera Baumer SXC20. Baumer SXC20 48 pages. Sxc series
cameralink cameras with truesense imaging
sensors
Also for Baumer SXC20: Quick Start Manual (2 pages)
Figure 42 ►
Tap geometry 1X-1Y.
The pixel information
is transmitted pixel-by-
pixel and line-by-line.
Figure 43 ►
Tap geometry 1X2-1Y.
Figure 44 ►
Tap geometry 1X3-1Y.
42
9.4.2. Tap Geometry
Since frame grabbers possess the ability of image reconstruction from multi-tap cameras
"on-the-fly", the CameraLink
ported tap geometries from the manufacturers of both, cameras and frame grabbers.
9.4.2.1.
Single
Tap Geometry
For single tap transmission the cameras of the Baumer SXC series employ the 1X-1Y tap
geometry:
9.4.2.2.
Dual
Tap Geometry
For dual tap transmission the cameras of the Baumer SXC series employ the 1X2-1Y tap
geometry:
9.4.2.3.
Tripple
Tap Geometry
For triple tap transmission the cameras of the Baumer SXC series employ the 1X3-1Y tap
geometry:
standards demands the specification of the used / sup-
®