11.2 Electrical data
Operating voltage V
S
Limits:
Reverse-protected
Ripple V
S
Power consumption
Current consumption
Average:
Peak (after switching on)
Connectors
Main connector
Interface connector
Output circuit
FLDM 170G...
normal state
FLDM 170C...
switchable voltage
Load resistance
Current load:
Short-circuit protected
Output pulse length
11.3 Pin assignment (looking at connector on Scatec)
Main connector
1
5
6
4
2
3
Interface connector
6
7
8
3
1
4
5
2
User manual Scatec-10 / -15
Version 2017-10
+10 VDC to +30VDC
yes
10% within the limits of V
< 2 W
< 170 mA
< 180 mA
DIN 45322, 6-pole, male
DIN 45326, 8-pole, male
push-pull
low
opto-isolated
maximum 40 V
maximum 50 kOhm
max. 100 mA
yes
selectable 0.3 ... 100ms
DIN 45322, 6 pole, male
Pin
Assignment
1
output signal +Vout
2
encoder input B
output signal -Vout
3
operating voltage +Vs
4
encoder GND
5
encoder input A
6
operating voltage GND (0V)
DIN 45326, 8 pole, male
Pin
Assignment
1
CAN_H
2
not connected
3
serial TxD (sensor)
4
CAN_L
5
serial RxD (sensor)
6
CAN_GND
7
serial GND
8
GND